Uncertainty measurement is one of the important indexes to quantitatively describe the quality of measurement results, which directly reflect the reliability, feasibility and comparability of the measurement results, meanwhile, keep the noise measured under the requirement of quality control. In this paper, By designing the air noise test of ship air compressor and scientifically calculating the uncertainty of the test, Starting from many factors affecting the vibration and noise test, and considering all factors affecting the test results, the scientific analysis system of uncertainty is used. A good reference basis is provided for the uncertainty calculation of subsequent tests. firstly measure the air noise of marine equipment based on GJB 4058-2000, then according to JJF 1059-2012, analyze and evaluate the uncertainty of measurement in detail: analyzing the sources of measurement uncertainty as well as giving the results of measurement uncertainty. scientific protection of sound level meter and other precision equipment should be considered especially. The environment in which the sound level meter is placed has a great influence on the sensitivity of the sound level meter, so the effectiveness of measurement can be improved by placing the sound level meter in the incubator after the measurement verification. This research is suitable for practical application.
Published in | American Journal of Mechanical and Industrial Engineering (Volume 6, Issue 5) |
DOI | 10.11648/j.ajmie.20210605.14 |
Page(s) | 77-80 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2021. Published by Science Publishing Group |
Air Noise, Measurement, Measurement Uncertainty, Analysis and Evaluation
[1] | Yu Lihua, The importance of measurement uncertainty. [J], Yunnan Electric Power University, 2010, 38 (6): 72-74. |
[2] | GJB 4058-2000, Measurement method of noise and vibration of ship equipment. [S]. |
[3] | ISO/IEC 17025-2005, General requirements for the competence of testing and calibration laboratories. [S]. |
[4] | JJF 1059.1-2012, Evaluation and expression of measurement uncertainty. [S]. |
[5] | Wang Chengmin, Ma Li, Sun Jia, Evaluation of measurement uncertainty of noise at plant boundary.[J], Environmental protection technology, 2012, 06 (18): 261-262. |
[6] | Xu Bo, Liu Congyue, Uncertainty analysis of phase noise measurement [J]. Electronic quality, 2008, (01): 9-13. |
[7] | Fei Yetai, error theory and data processing, Beijing: Machinery Industry Press, 2007. |
[8] | Ye Depei, measurement uncertainty, Beijing: Bureau of standards and metrology, commission of science, technology and industry for national defense, 1998. |
[9] | Xue Xiaoyan, interpretation of relevant parameters of air noise sound insulation, acoustic engineering, 2008. |
[10] | Qiu Lifan, Xi Yinong, Zhou Qingyun. Analysis and evaluation of measurement uncertainty of airborne sound insulation [C] / / Symposium on ship underwater noise for the 30th anniversary of the establishment of the underwater noise group of the academic committee of ship mechanics of China Shipbuilding Engineering Society. 2015. |
[11] | Cai Yangsheng, Zhao yuezhe. Comparative study on the uncertainty of sound insulation measurement by sound pressure method and sound intensity method [J]. Vibration and shock, 2018, 37 (008): 42-46, 53. |
[12] | Zhang Rong, Qin Haoming, Li Junzhao. Study on sound insulation test method of wall panel by sound pressure method in reverberation room semi anechoic room [C] 16th academic exchange meeting of China Aviation structure dynamics professional group. |
[13] | Deng Chunhui, Dong Shuhai, Luo Xizhen. Detection method and system of noise reduction effect of a composite sound insulation material:, cn104749256a [P]. 2015. |
[14] | Luo Yixi. Development and performance analysis of flexible noise reduction composites [J]. Industrial textiles, 2006 (04): 9-11. |
[15] | Luo Yixi, Shaoxing University of Arts and Sciences. Test and analysis of noise reduction performance of flexible noise reduction composites [C] China Textile Industry Association. China Textile Industry Association, 2008. |
APA Style
Yongchao Cheng, Chengming Dai, Miao Zhang, Yaofei Li. (2021). Research on Air Noise Measurement of Marine Equipment and Its Uncertainty. American Journal of Mechanical and Industrial Engineering, 6(5), 77-80. https://doi.org/10.11648/j.ajmie.20210605.14
ACS Style
Yongchao Cheng; Chengming Dai; Miao Zhang; Yaofei Li. Research on Air Noise Measurement of Marine Equipment and Its Uncertainty. Am. J. Mech. Ind. Eng. 2021, 6(5), 77-80. doi: 10.11648/j.ajmie.20210605.14
AMA Style
Yongchao Cheng, Chengming Dai, Miao Zhang, Yaofei Li. Research on Air Noise Measurement of Marine Equipment and Its Uncertainty. Am J Mech Ind Eng. 2021;6(5):77-80. doi: 10.11648/j.ajmie.20210605.14
@article{10.11648/j.ajmie.20210605.14, author = {Yongchao Cheng and Chengming Dai and Miao Zhang and Yaofei Li}, title = {Research on Air Noise Measurement of Marine Equipment and Its Uncertainty}, journal = {American Journal of Mechanical and Industrial Engineering}, volume = {6}, number = {5}, pages = {77-80}, doi = {10.11648/j.ajmie.20210605.14}, url = {https://doi.org/10.11648/j.ajmie.20210605.14}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajmie.20210605.14}, abstract = {Uncertainty measurement is one of the important indexes to quantitatively describe the quality of measurement results, which directly reflect the reliability, feasibility and comparability of the measurement results, meanwhile, keep the noise measured under the requirement of quality control. In this paper, By designing the air noise test of ship air compressor and scientifically calculating the uncertainty of the test, Starting from many factors affecting the vibration and noise test, and considering all factors affecting the test results, the scientific analysis system of uncertainty is used. A good reference basis is provided for the uncertainty calculation of subsequent tests. firstly measure the air noise of marine equipment based on GJB 4058-2000, then according to JJF 1059-2012, analyze and evaluate the uncertainty of measurement in detail: analyzing the sources of measurement uncertainty as well as giving the results of measurement uncertainty. scientific protection of sound level meter and other precision equipment should be considered especially. The environment in which the sound level meter is placed has a great influence on the sensitivity of the sound level meter, so the effectiveness of measurement can be improved by placing the sound level meter in the incubator after the measurement verification. This research is suitable for practical application.}, year = {2021} }
TY - JOUR T1 - Research on Air Noise Measurement of Marine Equipment and Its Uncertainty AU - Yongchao Cheng AU - Chengming Dai AU - Miao Zhang AU - Yaofei Li Y1 - 2021/11/05 PY - 2021 N1 - https://doi.org/10.11648/j.ajmie.20210605.14 DO - 10.11648/j.ajmie.20210605.14 T2 - American Journal of Mechanical and Industrial Engineering JF - American Journal of Mechanical and Industrial Engineering JO - American Journal of Mechanical and Industrial Engineering SP - 77 EP - 80 PB - Science Publishing Group SN - 2575-6060 UR - https://doi.org/10.11648/j.ajmie.20210605.14 AB - Uncertainty measurement is one of the important indexes to quantitatively describe the quality of measurement results, which directly reflect the reliability, feasibility and comparability of the measurement results, meanwhile, keep the noise measured under the requirement of quality control. In this paper, By designing the air noise test of ship air compressor and scientifically calculating the uncertainty of the test, Starting from many factors affecting the vibration and noise test, and considering all factors affecting the test results, the scientific analysis system of uncertainty is used. A good reference basis is provided for the uncertainty calculation of subsequent tests. firstly measure the air noise of marine equipment based on GJB 4058-2000, then according to JJF 1059-2012, analyze and evaluate the uncertainty of measurement in detail: analyzing the sources of measurement uncertainty as well as giving the results of measurement uncertainty. scientific protection of sound level meter and other precision equipment should be considered especially. The environment in which the sound level meter is placed has a great influence on the sensitivity of the sound level meter, so the effectiveness of measurement can be improved by placing the sound level meter in the incubator after the measurement verification. This research is suitable for practical application. VL - 6 IS - 5 ER -